5 Design and Function
enCore FC
Operating Instructions
Page 29 of 120
Device Type Connection Option
gas quality
measurement devices
serial interface
LAN interface
Table 1: Interface options
5.1.1 Number of Streams and their Flow Directions
The number of streams and their flow directions are variable since device
hardware and software can be extended. This number depends upon the
number of board slots available, individual hardware settings and the soft-
ware configuration.
5.1.2 International Standards
Flow Computers of the enCore FC device series support the following
international standards for the calculation of the gas characteristics which
are used for flow conversion. Which standards are supported in detail varies
according to device type:
Value Selectable Calculation Standard
compressibility AGA8-92 DC (ISO 12213-2)
SGERG-88 (ISO 12213-3)
AGA-NX19 mod
AGA-NX19 mod BR.KOR.3H
AGA-NX19 GOST
GOST 30319.2-2015
GOST 30319.3-2015
gas density, relative density AGA8-92 DC (ISO 12213-2)
ISO 6976
GOST 30319.3-2015
heating value, Wobbe index ISO 6976

Table of Contents

Other manuals for Honeywell enCore FC Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell enCore FC Series and is the answer not in the manual?

Honeywell enCore FC Series Specifications

General IconGeneral
BrandHoneywell
ModelenCore FC Series
CategoryDesktop
LanguageEnglish

Related product manuals