EasyManuals Logo

Honeywell enCore FC Series User Manual

Honeywell enCore FC Series
133 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #83 background imageLoading...
Page #83 background image
6 Assembly Instructions
enCore FC
Operating Instructions
Page 83 of 120
max. load: 24 V DC
6 mA
switching point:
> 15 V DC: (1)
< 6.5 V DC: (0)
max. input frequency depending on the operating mode:
LF: 8 Hz,
min. pulse length 50 ms
HF: 5 kHz
frequency (only channel 3): 5 kHz
(accuracy better than 1 ppm)
max. cable length depending on the operating mode:
message, LF or encoder: 500 m
HF up to 2 kHz: 250 m
HF up to 5 kHz: 100 m
frequency: 100 m