Figure 3-47 Alarms Configuration Interface
Table 3-22 Alarm Configurations
Parameter Description
Event Type Select from four types:
Local input alarm: The alarm signal system detects from the
alarm input port.
Network input alarm: An alarm signal from the network.
IPC external alarm: The on/off alarm signal from the camera,
which activates the local NVR to receive the IP camera’s alarm
if there is an alarm occurring at the camera.
IPC offline alarm: When enabled, the system generates an
alarm when the front end IP camera disconnects from the
local NVR. The alarm can activate recording, PTZ control, or
taking a snapshot, for example. The alarm can last until the
camera and the NVR connection resumes.
Alarm In Select a channel.
Enable Click to enable the this alarm configuration.
Device Type Select either Normally Open or Normal Closed.