Section 3: Programming the Communicator
21
PROMPTS OPTIONS DESCRIPTION
Important Information Regarding Primary and Secondary Accounts (Questions 12-18)
Account information is provided by the central station administrator. If the control panel supports secondary
account reporting, you will need secondary account information. The City ID, CS ID or Subscriber ID of the
secondary account must differ from that of the primary account.
13
Primary City ID
(??)_
[01-99]
Enter the 2-digit primary city ID, 01-99 (decimal).
14
Primary CS ID
(??)
[01-FE]
Enter the 2-digit primary central station ID number, 01-FE (HEX).
15
Primary Sub ID
(????)
[0001-9999]
Enter the 4-digit subscriber account number, 0001-9999 (decimal).
16
En. 2nd CS Y/N
(N)_
[Y], [N]
Applicable only if the control panel supports Central Station #1 and #2
Category Enable reporting for the communicator device (e.g., VISTA-
128BP, FA1660C).
Used if reporting to a second central station is desired.
If [N], go to Prompt 20: "Device Address."
17
2nd City ID
(??)_
[01-99]
Enter the 2-digit secondary city ID, 01-99 (decimal).
18
2nd CS ID
(??)_
[01-FE]
Enter the 2-digit second central station's ID number, 01-FE (HEX).
19
2nd Sub ID
(????)_
[0001-9999]
Enter the 4-digit subscriber account number for the second central
station, 0001-9999.
20
Device Address
(03)_
[01-30]
In ECP mode, the LTE-I communicates with the control panel using the
ECP bus. Enter the appropriate ECP device address. For VISTA-10
and VISTA-20 series control panels, use address 03. For other control
panels, see their Installation and Setup Guide.
NOTES:
1. When programming the control panel, enable the communicator (or
LRR) output.
2. The device address must be unique from the "Keypad Address"
entered in Prompt 23, and the “Multi-Mode Address” entered in
Prompt 12.
UL / ULC
Remote access has not been evaluated by UL or ULC.
21
Remote Access Y/N
(N)_
[Y], [N]
Press [Y] to allow the end user to access their system via a website.
Availability of this service is controlled by the dealer via the web-based
programming tool on the AlarmNet 360 website.
22
Direct Wire Y/N
(N)_
[Y], [N]
Applies only to VISTA-128BP/250BP and FBP Series control panels,
and FA1660C and 1700C Series control panels.
Enables Direct Wire Downloading over IP.
If [N], and if Prompt 21: "Remote Access" is disabled, skip to Prompt
24: "Supervision."
23
Keypad Address
(28)_
[01-30]
Must be programmed if using either the Remote Access feature or
Direct Wire downloading.
NOTES:
1. This address must also be programmed as an alpha keypad in the
control panel or an AUI (advanced user interface) type device, if a full
enhanced graphic interface to the system is desired and the control
panel supports it. DO NOT connect an actual keypad (or any other
device) assigned to this address.
2. This address must be unique from the "Device Address" entered in
Prompt 20.