RP-2002 Series Manual —
P/N 53039:E6 1/26/2017
9
WARNING!
When used for CO
2
releasing applica-
tions, observe proper precautions as
st
ated in NFP
A 12.
DO NOT enter the protected sp
ace
unless physical lockout and other safety
procedures are fully completed.
DO NOT use sof
tware disable functions
in the p
anel as lockout.
8
10
Table of Contents
Default Chapter
5
Table of Contents
5
Section 1: Product Description
13
Product Features
13
Specifications
14
Controls and Indicators
17
Components
18
Optional Modules and Accessories
18
Section 2: Installation
20
Backbox Mounting
20
Operating Power
23
Input Circuits
24
Output Circuits
27
1: Outputs/Notification Appliance/Releasing Circuits
27
Stat-X Aerosol Generators
28
2: Special Application DC Power Output Connections
29
3: Relays - Programmable
29
Power-Limited Wiring Requirements
30
Installation of Optional Modules
31
1: N-CAC-5X Class a Converter Module
31
Installation
31
Wiring Nacs and Idcs for Class a
32
2: 4XTM Municipal Box Transmitter Option Module
33
4XTM Transmitter Module Installation
33
3: ANN-SEC Option Card
34
ANN-BUS Devices
35
Guidelines
35
1: ANN-BUS Wiring
36
Calculating Wiring Distance for ANN-BUS Modules
36
Powering ANN-BUS Devices from Auxiliary Power Supply
38
2: ANN-BUS Device Addressing
39
3: N-ANN-80 Remote LCD Annunciator
39
Specifications
39
Installation
39
Wiring N-ANN-80 to FACP
40
Programming
41
4: N-ANN-S/PG Serial/Parallel Printer Interface Installation
41
Specifications
42
Printer Installation
42
Printer Installation
43
5: N-ANN-I/O LED Driver Module
45
N-ANN-I/O Board Layout
45
Specifications
45
N-ANN-I/O Connection to FACP
46
N-ANN-I/O Module LED Wiring
46
6: N-ANN-LED Annunciator Module
47
Specifications
47
Mounting/Installation
47
N-ANN-LED Board Layout and Connection to FACP
48
7: N-ANN-RLY Relay Module
48
Specifications
48
Mounting/Installation
49
N-ANN-RLY Board Layout and Connection to FACP
49
Section 3: Programming
50
User Programming
50
Initial Power-Up
51
Programming Screens Description
51
Programming and Passwords
52
Master Programming Level
53
1: FACP CONFIG (Application Templates)
53
2: Input Zones
54
3: Output Circuits
58
Enabled
58
Type
59
Silence
60
Auto Silence
60
Silence Inhibited
61
Coding
61
4: Cross Input Zones
63
5: On-Board Relays
63
6: System Setup
64
Abort Type
65
Timers
65
Banner
67
Time-Date
68
Trouble Reminder
69
Charger Disable
69
Canadian Option
69
Secondary ANN-BUS Option
70
7: Ann-Bus
70
ANN-BUS Enabled
70
ANN-BUS Modules
70
Auto-Configure
71
ANN-S/PG Options
71
ANN-I/O LED Zone Assignments
72
Options
72
ANN-RLY Options
73
8: History
74
View Events
75
Erase History
75
9: Walktest
75
10: Clear Program
76
11: Password Change
76
Maintenance Programming Level
77
1: Input Zones - Enable/Disable
77
2=History
77
3: Walktest
78
4: Time-Date
78
Section 4: Operating Instructions
80
Panel Control Buttons
80
1: Acknowledge/Step
80
2: Alarm Silenced (Domestic/Export Versions)/Signal Silence (Canadian Version)
80
3: Drill/Hold 2 Sec (Domestic/Export Versions)/Alarm Signal (Canadian Version)
80
4: Reset
80
Indicators
81
Normal Operation
81
Trouble Operation
82
Alarm Operation
83
Supervisory Operation
84
Disable/Enable Operation
84
Waterflow Circuits Operation
85
Detector Functions
85
Time Functions: Real-Time Clock
85
Coded NAC Operation
85
Release Stage/Nac Operation
85
Special System Timers
86
1: Silence Inhibit Timer
86
2: Autosilence Timer
86
3: Trouble Reminder
86
4: Pre-Discharge Delay Timers
86
5: Discharge Timers
86
6: Waterflow Delay Timer
86
Walktest
87
Read Status
87
1: FACP Configuration
88
2=Input Zones
88
3=Output Circuits
88
4: Cross Input Zones
89
5: On-Board Relays
89
6: System Settings
89
7: Timers
89
8: Daylight Savings
90
9: History
90
10: Print
90
11: Ann-Bus
90
Section 5: Power Supply Calculations
91
Overview
91
Calculating the AC Branch Circuit
91
Calculating the System Current Draw
92
1: Overview
92
2: How to Use Table 5.3 on Page 93 to Calculate System Current Draw
92
Calculating the Battery Size
94
1: NFPA Battery Requirements
94
2: Selecting and Locating Batteries
94
Appendix A: Circuit Mapping and Cross-Zoning
95
A.1: Input-To-Output Circuit Mapping and Cross-Zone Operation
95
A.1.1: Mapping Input Zones to Output Circuits for Direct Activation
96
A.1.2: Mapping Input Zones to Release Circuits for Cross Zone Activation
97
A.1.3: Complex Examples of Cross Zoning and I/O Mapping for Release Circuits
99
Appendix B: FACP Configuration Templates
100
B.1: Template 1: Cross-Zone System - with Horn
101
B.2: Template 2: Single Zone System with Horn
104
B.3: Template 3: Single Hazard - Cross-Zone
107
B.4: Template 4: Single Hazard - Count One
110
B.5: Template 5: Single Hazard - Single Detector, Cross-Zone NAC
113
B.6: Template 6: Single Hazard - Cross-Zone NAC
116
B.7: Template 7: Cross-Zone System - Bell/Horn/Strobe
119
B.8: Template 8: Single Hazard, Single Detector - Bell/Horn/Strobe
122
B.9: Template 9: Dual Hazard - Cross-Zone
125
B.10: Template 10: Dual Hazard - Single Detector
128
B.11: Template 11: Agent/Waterflow - Cross-Zone
131
B.12: Template 12: Agent/Waterflow - Single Detector
134
B.13: Template 13: HP CO2 Single Detector
137
Appendix C: NFPA Standard-Specific Requirements
140
C.1: NFPA 72 Auxiliary Fire Alarm System
143
C.2: Central Station/Remote Station Transmitter: Connection to FACP Dry Contacts
146
Appendix D: FACP with Keltron
147
Appendix E: Testing & Maintenance
148
E.1: Testing
148
E.1.1: Inspection
148
E.1.2: Alarm Test
148
E.1.3: Detector Testing
148
Test I 3 Series Detectors as Follows
149
E.2: Maintenance
149
Appendix F: Wire Requirements
150
F.1: NAC Wiring
151
Index
152
RP-2002, RP-2002E, RP-2002C Agent Release Control System Operating Instructions
157
5
Based on 1 rating
Ask a question
Give review
Questions and Answers:
Need help?
Do you have a question about the Honeywell NOTIFIER RP-2002C and is the answer not in the manual?
Ask a question
Honeywell NOTIFIER RP-2002C Specifications
General
Brand
Honeywell
Model
NOTIFIER RP-2002C
Category
Control Panel
Language
English
Related product manuals
Honeywell Notifier RP-2001
132 pages
Honeywell NOTIFIER RP1r
20 pages
Honeywell NOTIFIER N16
20 pages
Honeywell NOTIFIER NCA-2
108 pages
Honeywell Notifier ID3000
147 pages
Honeywell NOTIFIER NFW-50X
158 pages
Honeywell Notifier AFP-100
108 pages
Honeywell Notifier NFS-320
7 pages
Honeywell Notifier SFP-2404
56 pages
Honeywell NOTIFIER NFS-3030
4 pages
Honeywell Notifier LCD6000N
16 pages
Honeywell NOTIFIER NFW-100X
164 pages