Section 7 - System Programming
715
Question 10, L3
Arm Instant, Arming Stay Instant,
Instant Key Arms Away, Stay Key Arms Stay Default = 0
Digit
ARM INSTANT
ENABLE
ARM STAY/
INSTANT ENABLE
INSTANT KEY -
ARMS AWAY
STAY KEY -
ARMS STAY
0 NONE
1
9
2
9
3
9 9
4
9
5
9
9
6
9 9
7
9 9 9
8
9
9
9
9
A
9
9
B
9 9
9
C
9 9
D
9
9 9
E
9 9 9
F
9 9 9 9
ARM INSTANT ENABLE - If selected, this option allows the system to be armed in the Instant mode.
NOTE: If the [INSTANT] key is also enabled to Arm Away, only a keyfob can be programmed to Arm
Instant. This option must be selected to allow the keyfob to arm in this mode.
ARM STAY/INSTANT ENABLE - If selected, this option allows the system to be armed in the
Stay/Instant mode.
NOTE: If the [INSTANT] or [STAY] key is programmed to arm the system, only a keyfob can be used to
enable the system in this mode. This option must be selected to allow the keyfob to arm in this mode.
INSTANT KEY - ARMS AWAY - If this option is selected, pressing the [INSTANT] key on the keypad
will arm the system in the Away mode.
NOTE: To use this option, Quick Arming must be enabled in Question 07, Location 3.
STAY KEY - ARMS STAY - If this option is selected, pressing the [STAY] key on the keypad will arm
the system in the Stay mode.
NOTE: To use this option, Quick Arming must be enabled in Question 07, Location 3.