4–1
SECTION 4
System Operations
•••••••••••••••••••••••••••••••••••••••••••
In This Section
♦ Power-Up/System Reset
♦ Keypads
♦ Keypad Sounder
♦ Keypad Backlight Timer
♦ Keypad Addressing
♦ Arming the System
♦ Reset
♦ Bypass
♦ Subsequent Bypasses
♦ Quick Bypass
♦ Exit Bypass
♦ Auto Unbypass
♦ Manual Unbypass
♦ User Code Programming
♦ User Deletion
♦ Keypad Emergency Conditions
♦ Pager Follow-Me Displays
♦ Entering Pager Follow-Me Phone Numbers
•••••••••••••••••••••••••••••••••••••••••••
Power-Up/System Reset
When the system is in an armed state only, it may enter System Stabilization Mode. This occurs upon
power-up of the system, and causes all of the LEDs on the keypad(s) to light, and then go off for
approximately 2 minutes (if system was previously armed). This occurs on a total power-up or system
reset. If total system power is lost, upon power restoration, the system returns to the previous arming
state. The 2-minute, 10-second interval is used to allow motion detectors (in interior zones) to stabilize
on power-up in order to prevent false alarms. THIS OPTION CAN BE DISABLED BY PUTTING A
MOMENTARY JUMPER BETWEEN TERMINALS 15 AND 16 ON POWER-UP. IF DISABLED, THE
POWER-UP RESET TIME IS APPROXIMATELY 10 SECONDS. This is a normal condition.