Section 7 - System Programming
717
BURGLARY (CONTROLLED) ZONES
ZONE TYPE ZONE OPTIONS
L1, L2
Digits
INSTANT
(PERIMETER)
DELAY
(EXIT/ENTRY)
INTERIOR
FOLLOWER
CHIME DAY
BYPASS
IN STAY
DIALER
DELAY
10
9
None (Instant Zone w/o Options)
11
9
9
12
9
9
13
9
9 9
14
9
9
15
9
9
9
18
9
9
19
9
9 9
1A
9
9
9
1B
9
9 9 9
1C
9
9
9
1D
9
9
9 9
20
9
None (Delay Zone w/o Options)
21
9
9
24
9
9
25
9
9
9
40
9
None (Interior Zone w/o Options)
41
9
9
44
9 9
45
9 9
9
48
9
9
49
9
9 9
4C
9 9
9
4D
9 9
9 9
Burglary (Controlled) Zones
DELAY - This is the industry standard exit/entry zone. When the system is armed, exit time begins.
After the exit time expires, any violation of this zone begins entry time. If the system is not disarmed
within the programmed entry time, an alarm occurs. The keypad sounder annunciates steadily during
entry time, unless there has been an alarm condition, in which case it pulses. Delay zones activate
instantly when the system is armed using the Instant and Stay/Instant mode, if enabled. Delay zones
employ the Exit Error Warning feature described below.