EasyManuals Logo

Honeywell ST 3000 Installation Guide

Honeywell ST 3000
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #105 background imageLoading...
Page #105 background image
Index
2/05 ST 3000 Release 300 Installation Guide 95
Flange mounted, 23
A
Flat mounting bracket, 23
Flow engineering units
Analog meter connections, 44
Smart meter, 58
Analog mode, 7, 10, 13, 21
Flush mounted transmitter, 30
Angle mounting bracket, 23
G
B
Ground
Barriers, 40
External ground, 42
Battery pack, SFC
Ground terminal, 39
Installing and charging, 20
Bench check, 5
H
Blow-down lines, 34, 37
Hazardous locations reference, 82
Bracket mounting
IEC Classifications, 88
Horizontal pipe, 24
North American Classifications, 82
Vertical pipe, 24
C L
Capillary tubes, 32 Leveling an absolute pressure transmitter, 27
Checking ST 3000 shipment, 2 Lightning Protection, 42
Communications, 7 Local Smart Meter
Communicating with the ST 3000, 4 Setting display of LRV (using meter pushbuttons), 62
Testing, 7 Local Zero and Span
Conduit seal, 43 Adjusting (Procedure), 53
Loop resistance, 39
D
Loop wiring, 44
Digital (DE) mode, 7, 13, 21
M
Dimensions, 24
Model designations, 2
E
Mounting locations
Suggested, 35
Electronics housing. See Transmitter housing
Electronics module, PWA, 13
O
Enclosure ratings, 93
Output conformity and smart meter configuration, 58
F
Overpressure ratings, 19
Failsafe action, 13
P
Failsafe direction, 13
change, 13
Piping for a 1/2" NPT process connection, 35
Piping guidelines, 37
Failsafe jumper, 13
Potential noise sources, 17
Fill-fluid, 18
Power supply, 5
Fill-fluids, 32
connecting, 5
Flange adapter, 34
Power supply voltage, 21, 39
Installing, 38
Pressure ratings, 19
Flange connections, 37
Process characteristics, 17
Extended, 37
Process connections, 36
Flush, 37

Table of Contents

Other manuals for Honeywell ST 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell ST 3000 and is the answer not in the manual?

Honeywell ST 3000 Specifications

General IconGeneral
ManufacturerHoneywell
CategoryTransmitter
Stability±0.01% of URL per year
Operating Temperature-40 to 85°C (-40 to 185°F)
Communication ProtocolHART
Housing MaterialAluminum or Stainless Steel
Enclosure RatingIP66/67, NEMA 4X
Measurement TypeGauge, Absolute, Differential
Output Signal4-20 mA, HART
Process Temperature-40 to 121°C (-40 to 250°F)
Hazardous Area ApprovalsFM, CSA, ATEX, IECEx
Process Connection1/2" NPT
Material316L Stainless Steel, Hastelloy C

Related product manuals