IMPORTANT
Before You Begin, Please Note
Transmitter Terminal
Blocks
Depending on your transmitter options, the transmitter may be equipped
with either a 3-screw or 5-screw terminal block inside the electronics
housing. This may affect how to connect the loop wiring and meter
wiring to the transmitter. See Section 4.3 for the terminal block
connections for each type terminal. Section 5 provides additional wiring
diagrams showing alternate wiring methods.
-
S
I
G
N
A
L
+
+
-
T
E
S
T
Terminal
Block
Electronics
Housing
Internal
Ground
Terminal
3-Screw Terminal Block
+
+
-
-
L-
S
I
G
N
A
L
M
E
T
E
R
T
E
S
T
S
I
G
N
A
L
-
+
+
-
Terminal
Block
Electronics
Housing
Internal
Ground
Terminal
5-Screw Terminal Block
2/05 ST 3000 Release 300 Installation Guide
ix

Table of Contents

Other manuals for Honeywell ST 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell ST 3000 and is the answer not in the manual?

Honeywell ST 3000 Specifications

General IconGeneral
ManufacturerHoneywell
CategoryTransmitter
Stability±0.01% of URL per year
Operating Temperature-40 to 85°C (-40 to 185°F)
Communication ProtocolHART
Housing MaterialAluminum or Stainless Steel
Enclosure RatingIP66/67, NEMA 4X
Measurement TypeGauge, Absolute, Differential
Output Signal4-20 mA, HART
Process Temperature-40 to 121°C (-40 to 250°F)
Hazardous Area ApprovalsFM, CSA, ATEX, IECEx
Process Connection1/2" NPT
Material316L Stainless Steel, Hastelloy C