C-1
A P P E N D I X C
Specifications
VISTA-128BPT/VISTA-250BPT CONTROL
Physical:
Standard Cabinet (included) 12 1/2" W x 14 1/2" H x 3" D
UL Cabinet (optional) 14 1/2" W x 18" H x 4.3" D (Included in the COM-UL Commercial Enclosure)
Electrical:
Voltage Input: From ADEMCO No. 1361 Plug-In Transformer (use 1361CN in Canada) rated
16.5VAC, 40 VA.
Alarm Sounder Output: 10VDC-13.8VDC, 1.7A max. (UL1023, UL609 installations); 750mA less aux. current
draw (UL985 installations).
Auxiliary Power Output: 9.6VDC-13.8VDC, 750mA max. For UL installations, the accessories connected to the
output must be UL Listed, and rated to operate in the above voltage range.
Backup Battery: 12VDC, 4AH or 7AH gel cell. YUASA NP4-12 (12V, 4AH) or NP7-12 (12V, 7AH)
recommended.
Standby Time: 4 hours min. with 750 mA aux. load using 7 AH battery.
Circuit Protectors: PTC circuit breakers are used on battery input to protect against reverse battery
connections and on alarm sounder output to protect against wiring faults (shorts).
A solid-state circuit breaker is used on auxiliary power output to protect against wiring
faults (shorts).
Digital Communicator
Formats Supported: 4 + 2 Express, Contact ID and 10-Digit Contact ID
Line Seize: Double Pole
Ringer Equivalence: 0.7B
FCC Registration No.: AC398U-68192-AL-E
Remote Keypads
6160
Physical:
Width: 7.437 inches
Height: 5.25 inches
Depth: 1.312 inches
Electrical:
Voltage Input: 12VDC
Current Drain: 150mA
Interface Wiring:
RED: 12VDC input (+) auxiliary
power
GREEN: Data to control panel
YELLOW: Data from control panel
BLACK: Ground and (-) connection from
supplemental power supply
6160V
Physical:
Width: 7 3/8 inches
Height: 5 5/16 inches
Depth: 1 3/16 inches
Electrical:
Voltage Input: 12VDC
Current Drain: 190mA
Interface Wiring:
RED: 12VDC input (+) auxiliary power
GREEN: Data to control panel
YELLOW: Data from control panel
BLACK: Ground and (-) connection from supplemental power supply