4-1
S E C T I O N 4
Programming
NOTE: All references in this manual for number of zones, number of user codes, number of access cards,
and the dialer queue capacity, use the VISTA-250BPT’s features. See SECTION 1: General Description for
the table listing the differences between the VISTA-128BPT and the VISTA-250BPT control panels.
Program Modes
There are two programming modes for the VISTA-
128BPT/VISTA-250BPT. These are the Data Field
Program Mode and the #93 Menu Mode. The Data Field
Program Mode is where many system options are
programmed. The #93 Menu Mode is an interactive
mode that requires a 2-line alpha keypad (6160).
The factory-loaded defaults (97) enable
keypad addresses 00-01 only. A keypad set to
one of these addresses must be used to
program the system initially.
Local keypad programming can be disabled
through Compass downloading software. If this
is done, Program mode can only be accessed
via the downloading software.
Entering and Exiting Programming Mode
Enter Programming mode using either method a or b:
a. Press both the [] and [#] keys at the same time
within 30 seconds after power is applied to the
control.
b. Enter the Installer Code + [8] + [0] + [0] + [0]
keys. The factory installer code can be changed
once in the Program mode (field 00).
NOTE: The default for the Installer Code is 4140.
Exit the Programming mode by either method a or b:
a. Press [] + [9] + [8]. Exiting by this method
prevents the installer code from being used to re-
enter Programming mode. Only method “a” can be
used to re-enter Programming mode.
b. Press [] + [9] + [9]. Exiting by this method
permits the installer code to be being used to re-
enter Programming mode.
Data Field Programming Mode
In the Data Field Program Mode you may access any
field simply by entering either [] or [#] + the field
number:
To write or change information in a field press [] +
the field number (03).
To read the information in a field press [#] + the
field number (03).
When the entries for a field are completed, the keypad
beeps three times and advances to the next field.
Summary of Data Field Programming Commands
91
Select partition for programming partition-specific fields
92
Display the software revision level of the control panel
93
Enter Menu mode programming
94
Go to next page of fields
99
Go back to previous page of fields or exit Programming
Mode with no installer code lockout
98
Exit Programming Mode with Installer Code lockout
Moving Between Programming Levels
The data fields are grouped into three levels (referred to
as “pages”). The first page is accessed as soon as
Programming Mode is entered.
The second and third pages of data fields are indicated
at the keypad by a 1 and 2, respectively, in front of the
2-digit field address. “ALT PROGRAM MODE” is
displayed along with a “100” or “200,” indicating which
page of program fields is accessed.
To access the next level of programming fields, perform
the following steps:
Step Action
1
Press 94.
2
Press [] + [XX], where XX = the last two
digits of the program field, and make the
desired entry.
NOTES:
Press 94 to move to 2
nd
page, (fields 101 - 180); press
99 to move back to 1
st
page.
Press 94 to move to 3
rd
page (fields 200 - 224); press
99 to move back to 2
nd
page
Entry Errors
If an address is improperly entered, the keypad
displays “FC.”
If a program entry is improperly entered (for
example, a larger number than is permitted), the
keypad display will go blank.