1-1
S E C T I O N 1
General Description
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
About the VISTA-128BPT/VISTA-250BPT
All references to the VISTA-128BPT also pertain to the VISTA-128BPTSIA. The differences between the two panels
are outlined in the SIA CP-01 Quick Reference Chart located at the beginning of this manual.
The VISTA-128BPT/VISTA-250BPT is an 8-partition, UL Listed control panel with the following features:
• Supports hardwired, polling loop, and wireless zones
• Supervision of bells, keypads, RF receivers, and output devices
• Scheduling capabilities (allows certain operations to be automated)
The VISTA-128BPT/VISTA-250BPT can interface with the following devices:.
• Up to six 6280 Graphic/Touch-Screen keypads
• AlarmNet Total Connect (Remote Interactive Service) allows access from a wireless smart phone or web browser via
any Total Connect 2 compatible AlarmNet device.
• Voice Keypad (6160V)
U
L
Voice Keypad 6160V cannot be used for SIA Installations
.
• An ECP Communication Device that can send Contact ID messages
• An access control system by using the ADEMCO VistaKey module (via the polling loop)
U
L
The access control function is not Listed for use with the VISTA-128BPT/VISTA-250BPT Control Panel in a UL
installation.
NOTE: All references in this manual for number of zones, number of user codes, number of access cards,
and the event log capacity, use the VISTA-250BPT’s features. The following table lists the differences
between the VISTA-128BPT and the VISTA-250BPT control panels. All other features are identical.
Feature VISTA-128BPT VISTA-250BPT
Number of Zones 128 250
Number of User Codes 150 250
Number of Access Cards 250 500
Event Log Capacity 512 1000
VistaKey Modules 8 15