viii
Item Feature Range Shipping
Default
SIA
Requirement*
Zone
Programming
(Abort
Window
Enable)
Abort Window (for
non-fire zones)
0 = no abort window
1 = yes, use abort
window according to
88 selection
1 = yes
Yes (all non-fire
zones)
Zone
Programming
(Swinger
Suppression
Enable)
Swinger Suppression
Enable
0 = no suppression
1 = yes, suppress
alarms according to
84 selection
Yes (enabled)
Yes (enabled (all
zones))
Zone
Programming
Tamper
Option
Fire Alarm Verification
For Zone Response
Type 16 (Fire) tamper
selection must be set to
“0”
Disabled
Enabled unless
sensors can self verify
-
Exit Time and
Progress
Annunciation/Disable
for Remote Arm (Not
Evaluated for SIA CP-
01)
Always Enabled Enabled Enabled
-
Programmable Cross
Zoning Time
Both zones must be
faulted within 5 minutes
Per Manufacturer
Per walk path in
protected premises
- Cancel Window 5 minutes Enabled
Not required to be
programmable
-
Cancel Annunciation -
Keypad displays
“Alarm Cancel” when
report is received
NA Enabled Enabled
User
Authority
Level 6
Duress Feature NA Disabled Disabled
* Programming at installation may be subordinate to other UL requirements for the intended application.
** Combined Entry Delay and Abort Window should not exceed 1 minute.
NOTES:
Using the Call Waiting Cancel feature on a non-Call Waiting line will prevent successful communication to the
central station.
The control unit must be installed with a local sounding device and an off-premise transmission for Contact ID
communication format.
Refer to the User Guide for procedures on Testing the System.
During Test mode, no alarm reports are sent to the central monitoring station.