VISTA-128BPT/VISTA-250BPT Installation and Setup Guide
4-4
Following is a list of commands used while in the Menu Mode:
#93 Menu Mode Programming Commands
#93
Enters Menu Mode.
[∗]
Serves as [ENTER] key. Press to have keypad accept entry.
[#]
Backs up to previous screen.
0
Press to answer NO.
1
Press to answer YES.
00, or 000+[∗]
Quits Menu Mode and goes back to Data Field Programming Mode, if entered at first prompt of each main menu option.
Zone Number Designations
The VISTA-128BPT supports up to 128 zones, the
VISTA-250BPT supports up to 250 zones, of hardwire,
polling loop and/or wireless protection, distributed
among up to eight partitions. The following table lists
the zone numbers and the types of sensors that can be
used with each, and some alternate functions of the
zones.
Zone
Function
1 2-wire Smoke Detectors (if used)
5 Audio Alarm Verification (if used)
7 Keyswitch (if used)
1-9 Traditional Hardwired Zones
9 For unsupervised, N.C. use only.
1-250 5800 Series Wireless Devices
10-250 Polling Loop Devices
995
∗ + 1 Panic
996 # + 3 Panic
999
∗ + # Panic
Zone Defaults
Zone # Zone Type Zone # Zone Type
001 09 601-632 00
002 03 800-830 00
003 03 970 00
004** 04 988 00
005 03 990 00
006 03 992* N/A
007 03 995 00
008 03 996 00
009 03 997 05
010–250 00 999 06
NOTES:
* Zone 992 is the Duress zone. Programming of the zone
response type is not applicable. This zone requires only the
report code programming.
** Zone 004 is also defaulted with Auto-STAY enabled.
Zone Index
The zones are designated as follows:
ZONE #
RANGE
ZONE
FUNCTION
ACTUAL ZONE
001 – 250
Protection
zones
As indicated
601 – 632
Relay
Supervisory
Zones
6 + 2-digit Relay Number; e.g.,
Relay Number 03 is zone 603.
800 – 830
ECP Device
Supervisory
Zones
8 + 2-digit Device Address; e.g.,
Device Address 01 is zone 801.
970, 988,
990, & 997
System
Supervisory
Zones
970: Bell Supervision
988: 2
nd
Wireless Receiver –
not receiving signals
990: 1
st
Wireless Receiver –
not receiving signals
997: Polling Loop (short
circuit)
992, 995 –
999
Duress and
Keypad
Panics
992: Duress
995: 1 + ∗ panic (A key)
996: 3 + # panic (C key)
999: ∗ + # panic (B key)
Program supervisory zones with response type of 05.
Communication Defaults
∗45 PRIMARY FORMAT [1]
ADEMCO Contact ID
∗47 SECONDARY FORMAT [1]
ADEMCO Contact ID
∗51 DUAL REPORTING [0]
no