VISTA-128BPT/VISTA-250BPT Installation and Setup Guide
5-6
FIELD
TITLE and DATA ENTRIES EXPLANATION
∗
∗∗
∗88
Abort Window (partition-specific)
0 = no delay
1 = 30-second delay
Select the delay, if any, for burglary alarm communications.
Must be 0 for UL installations.
∗
∗∗
∗89
Restore Report Timing
0 = instant
1 = after bell timeout
2 = when system is disarmed
Select the time when restore reports are sent after an alarm.
Must be 2 for UL installations.
∗
∗∗
∗90
Secondary Subscriber Account
Number (partition-specific)
Enter 00-09; B-F (11-15)
Enter a 4- or 10-digit (depending on report format) primary subscriber account
number. Each number requires a 2-digit entry so as to allow entry of
hexadecimal digits (B-F). If a 4-digit account number is to be used, enter data
only in the first four locations, and enter ∗ in the fifth location.
NOTE: This field must be programmed if a secondary phone number is used
(field ∗34). This account number can be the same as the primary account
number.
1∗
∗∗
∗07
Check or TRBL Display
0 = CHECK
1 = TRBL
Select whether the system should display TRBL or CHECK for trouble
conditions.
1∗
∗∗
∗11
Zone Bypass After Disarm
0 = disable
1 = enable
This field has eight entries, one for each partition. For each partition in which
“1” is entered, zones will remain bypassed after the system is disarmed..
NOTES:
For each partition in which field 1∗11 is enabled, the USER CODE + OFF will
no longer unbypass zones. To unbypass ALL zones, you must enter USER
CODE + # + 64. To unbypass zones INDIVIDUALLY, you must enter USER
CODE + 6 + zone number.
Any zone that was automatically bypassed by the system will be unbypassed
upon disarming of the system (e.g., STAY mode, Auto-STAY, etc.).
Vent zones and zones bypassed by a programmed Auto-Bypass schedule
(Timed Driven Event) are considered “manual bypasses” and will not be
unbypassed upon disarming the system.
Zones that were in a bypassed state at the time a System Shutdown is sent
from the Compass Downloading software will be unbypassed when the
System Shutdown is removed.
1∗
∗∗
∗15
Cancel Verify
0 = disable
1 = enable alarm output pulse upon kissoff of
Cancel report.
NOTE: Field 1∗52 must be enabled to send a Cancel report to the central
station.
1∗
∗∗
∗17
Lobby Partition
0 = none
1-8 = partition number
Select the Common Lobby Partition.
1∗
∗∗
∗18
Affects Lobby (partition-specific)
0 = disable
1 = enable
If enabled, causes lobby partition to disarm when this partition disarms.
NOTE: This partition must be armed before lobby can be armed.
1∗
∗∗
∗19
Arms Lobby (partition-specific)
0 = disable
1 = enable
If enabled, arming this partition causes the system to attempt to arm the lobby
partition automatically. To enable this field, field 1∗18 must also be enabled
(partition-specific).
NOTES:
The lobby cannot be armed unless all partitions programmed for “affect” (field
1∗18) is already armed.
If his field is enabled, Field 1∗18 for this partition must also be enabled.