EasyManua.ls Logo

Honeywell VISTA-128BPT - Page 78

Honeywell VISTA-128BPT
124 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VISTA-128BPT/VISTA-250BPT Installation and Setup Guide
6-10
Action Code Action Action Specifier
72 Access Point Exit by Partition Partition #
73 Access Point Trigger On Trigger #
74 Access Point Trigger Off Trigger #
77 Access Point Group Enable Group #
78 Access Point Group Disable Group #
3. Enter the desired activation time (when the action is to take place). Select from:
Activation
Time
Description
1 Beginning of time window.
2 End of time window.
3 During time window active period only (on at beginning of window, off at end).
For example, if bypass is selected to activate during the window, zones in a zone list are bypassed at the beginning of
the window and unbypassed at the end of the window.
4 Beginning and end of time window (e.g., a coffee break buzzer). In this example, if relay pulse is selected, the relay
pulses for 2 seconds at the beginning of the window, signaling the beginning of the coffee break. At the end of the
window it pulses again, signaling the end of coffee break.
5 Random time at the start of the time window (occurs within 30 minutes after the start of the time window).
NOTE: Since the randomization for choice “5” occurs within 30 minutes after the start of the window, the time
window must be at least 30 minutes in duration.
6 Random time at the end of the time window (occurs within 30 minutes after the end of the time window).
7 Random during the time window (begins within 30 minutes after the start of the time window and ends within 30
minutes after the end of the time window).
NOTE: Since the randomization for choice “7” occurs within 30 minutes after the start of the window, the time
window must be at least 30 minutes in duration.
Field 04 must be enabled for randomization. A user must initiate a random schedule by entering one of the following
sequences:
[User Code] + [#] + [41]. This will randomize, up to 30 minutes, the activation time of all devices, programmed for
randomization, assigned to the partition the sequence is entered in. Enter the sequence again to turn off the random
schedule.
[User Code] + [#] + [42]. This is the same as the method above, except the randomization occurs only on devices
with activation times within 6 PM and 5 AM. Enter the same sequence again to turn off the random schedule.
U
L
You must not program Random Scheduling of Time Driven Events for UL installations.
Time-Driven Events Programming
The following menu items must first be programmed in Output Programming in the #93 Menu Mode:
Enter Relay No. (reference identification number)
Output Group (if applicable)
Restriction
Output Type (V-Plex or 4204)
Zone No. (V-Plex)
ECP Address (4204)
Relay No. (4204)