DescriptionDefault ValueRegistry Key
Enables the Plessey symbology.0x0PlesseyActivation
Not documented.0x0PlesseyUnconventionalStop
A single character inserted before the barcode data to
indicate the symbology.
0x44PlesseyCodeMark
Length value L1. Range is 0x0 to 0xFF (0 to 255).0x0PlesseyBarCodeLengthL1
Length value L2. Range is 0x0 to 0xFF (0 to 255).0x0PlesseyBarCodeLengthL2
Length value L3. Range is 0x0 to 0xFF (0 to 255).0x0PlesseyBarCodeLengthL3
Length verification mode, where 0 = "L1 is min length", 1 =
"L1, L2, L3 are fixed lengths", and 2 = "L1 is min, L2 is max
length".
0x0PlesseyBarCodeLengthMode
Enable transmission of the check digit.0x0PlesseyCheckDigitTransmission
User-defined symbology identifier. Range is 0-4 characters."C2"PlesseyUDSI
[HKEY_LOCAL_MACHINE\Software\Vocollect\Imager\Standard 2 of 5] - Standard 2 of 5 Symbology Configuration
Enables the Standard 2 of 5 symbology.0x0Standard2of5Activation
A single character inserted before the barcode data to
indicate the symbology.
0x44Standard2of5CodeMark
Enables modulo 10 calculation of check digits.0x0Standard2of5CheckDigitVerification
Length value L1. Range is 0x0 to 0xFF (0 to 255).0x6Standard2of5BarCodeLengthL1
Length value L2. Range is 0x0 to 0xFF (0 to 255).0x0Standard2of5BarCodeLengthL2
Length value L3. Range is 0x0 to 0xFF (0 to 255).0x0Standard2of5BarCodeLengthL3
Length verification mode, where 0 = "L1 is min length", 1 =
"L1, L2, L3 are fixed lengths", and 2 = "L1 is min, L2 is max
length".
0x0Standard2of5BarCodeLengthMode
Enable transmission of the check digit.0x0Standard2of5CheckDigitTransmission
Specifies read mode, where 0 = Identicon (6 start/stop bars)
and 1 = Computer Identics (4 start/stop bars).
0x0Standard2of5Format
User-defined symbology identifier. Range is 0-4 characters."B5"Standard2of5UDSI
[HKEY_LOCAL_MACHINE\Software\Vocollect\Imager\Telepen] - Telepen Symbology Configuration
Enables the Telepen symbology.0x0TelepenActivation
A single character inserted before the barcode data to
indicate the symbology.
0x2aTelepenCodeMark
Length value L1. Range is 0x0 to 0xFF (0 to 255).0x0TelepenBarCodeLengthL1
Confidential: For informational use by Honeywell resellers and customers only
Talkman A730 Symbologies | 71