15.6 Configuration
An overview of configuration:
(1) Start the configuration by selecting the Controller Hardware Configure menu item.
(2) If the XLE/XLT is connected to the PC press the Auto Config System button to
automatically detect the Base model, I/O and any communication options.
(3) If the XLE/XLT is not connected press the Config button to the right of the top of the
unit. This allows the base CPU to be selected.
(4) Select either XLE/XLT CsCAN or XLE/XLT No Net from the type drop down box.
(5) Once the type of XLE/XLT is selected, the model # drop down box will provide the
XLE/XLT model numbers from which to choose from.
(6) Once the XLE/XLT CPU is selected, press OK to exit the dialog and configure the I/O that
is present in the first slot.
(7) The I/O configure dialog (Specifically the Module Setup tab) provides four buttons to
configure all the I/O. Go through each area of I/O and configure it.
(8) Once done configuring the I/O OK out of configuration dialogs.
Configuring the XLE/XLT I/O has four main portions that are covered in this chapter. For
additional information on I/O, refer to the chapters covering General I/O or High Speed I/O in
this manual.
The four areas of Module Configuration are Digital In / HSC, Digital Out / PWM, Analog In,
Analog Out.