CHANGING SETTINGS ON THE SUPERUSER MENU
SERVICE MANUAL 27
Reheat Pulse Interval
You use the Reheat pulse interval setting to specify the interval in seconds between injec-
tions of water during the regeneration process. The injection itself lasts 1/10 of a second.
The default setting is 8 seconds.
1. On the SuperUser display, touch Adjustments, and then touch Reheat pulse
interval.
2. Drag your finger up or down to select from 4s to 24s in intervals of 2 and then
touch OK.
Proving Pulse Interval
You use the Proving pulse interval setting to specify the interval in seconds between injec-
tions of water during the proving process. The injection itself lasts 1/10 of a second. The
default setting is 20 seconds.
1. On the SuperUser display, touch Adjustments, and then touch Proving pulse
interval.
2. Drag your finger up or down to select from 12s to 44s in intervals of 4, and then
touch OK.
Proving Pulse Length
You use the Proving pulse interval setting to specify for how long each injection of water
lasts during the proving process. The default setting is 1 second.
1. On the SuperUser display, touch Adjustments, and then touch Proving pulse
length.
2. Drag your finger up or down to select the preferred length: 0.6, 1.0 or 2.0
seconds, and then touch OK.