ERROR CODES
SERVICE MANUAL 69
Gas Error Codes
Error codes from number 50 to 67 are gas oven specific.
Error 50/60
Pressure switch error. The pressure switch is active at start (timeout 20 sec.)
Steps Check list Solution
1 Go to the test menu, and adjust the
pressure switch. (See Appendix D:
Touch controller “XPE” – Set-up and
Adjustment on page 82).
Verify that it the pressure switch is working
properly.
Change the pressure switch.
Error 51/61
Pressure switch error. The pressure switch is not active when the gas fan is running.
Steps Check list Solution
1 Go to test function.
Check that the relay K16 is working
properly.
2 Adjust the pressure switch.
(See Appendix D:
Touch controller “XPE” – Set-up and
Adjustment on page 82).
Verify that it the pressure switch is working
properly.
Change the pressure switch.