ERROR CODES
54 SERVICE MANUAL
Error Code 6
The drain temperature has been above 75°C/167°F for more than 5 minutes. It is
normally kept below 60°C/140°F.
Steps Check list Solution
1 Check that the water is turned on.
2 Check that the water supply connected to
the oven is cold and not hot.
3 Check whether the temperature sensor
is broken. (Measure the real temperature
and compare it to the temperature
measured by the test function.)
If broken, change the sensor.
4 Clean the jet and the solenoid valve at the
drain, and then check the temperature
again.
Change the computer.
Error Code 7
The temperature sensor in the oven chamber is broken. The oven cannot be used until
the error has been corrected.
Steps Check list Solution
1 Go to the test menu (oven) to see which
temperature is displayed.
2 Check the cable and the cable plugs and
change the plug if necessary.
3 Test the sensor using an ohmmeter,
and check whether the value matches
the value in the table and the current
temperature.
If no, change the sensor.
4 - Change the computer.