ERROR CODES
56 SERVICE MANUAL
Error Code 10
The temperature sensor in the drain is broken. The oven can still be used, but the error
has to be corrected as soon as possible.
Steps Check list Solution
1 Go to the test menu (oven) to see which
temperature is displayed.
2 Check the cable and the cable plugs and
change the plug if necessary.
3 Test the sensor using an ohmmeter,
and check whether the value matches
the value in the table and the current
temperature.
If no, change the sensor.
4 - Change the computer.
Error Code 11
There’s not enough water. The steam generator was not filled to high level water within 2
minutes.
Steps Check list Solution
1 Go to the test menu (steam generator) to
see if the water level is correct. Adjust the
water level if necessary. Check that water is
turned on. The water pressure should be at
least 2 bars.
2 Test whether the solenoid valve and
the level sensor are working (is 24VAC
measured at the coil when the fill valve is
activated?)
Clean the solenoid valve.
3 - Change the computer.