ERROR CODES
66 SERVICE MANUAL
Error Code 39
There is insucient memory to run the selected operation.
Steps Check list Solution
1 - If possible, delete some
HACCP files.
Error Code 40
The IO board temperature has been too high. Note that this is a warning. If the temper-
ature continues to rise, the oven will stop and display error code 16.
Steps Check list Solution
1 Clean the filter at the bottom of the panel
and check that the cooling fan behind the
front panel is running.
Clean the filter at the bottom
of the panel.
2 Check that the cooling fan behinde the
front panel is running.
Replace coolingfan if
neccessary.
Error Code 41
Main Alarm. Boiler overheating safety switch was tripped, in a function mode that does
not use the boiler
Steps Check list Solution
1 Check if the overheat safety switch have
been tripped.
Reset the overheat safety
switch.
2 Check the jumper on wires