APPENDIX C: GAS BURNER SETTINGS
SERVICE MANUAL 81
Adjustment “ETL” gas ovens (burner 2)
Houno Gas Oven Adjustment Settings Convection Burner 2 “Top”
O
2
%, CO
2
%
“MAX” RPM
O
2
%, CO
2
%
“MIN”, RPM
RPM Adjustement
normal operation
Air Proving
Switch - ON
Type of Gas
Heat
Power
BTU/hr
Ovn
Types
Gas inlet
Pressure
O
2
% CO
2
% RPM BTU/hr O
2
% CO
2
% RPM
“u17”
Min
“u17”
Start
“u17”
Max
OFF -> ON
NAT
(G20)
58000 1.06/5 3,2-8,0 inH
2
O
87000 1.10/8 3,2-8,0 inH
2
O
174000 1.20/15 3,2-8,0 inH
2
O 4,3% 9,3% 6300 87000 4,1% 9,4% 2700 2700 3900 6300 2300 ±100
81800 2.06 3,2-8,0 inH
2
O
95500 2.10 3,2-8,0 inH
2
O
190000 2.20 3,2-8,0 inH
2
O 4,1% 9,4% 6600 95500 4,5% 9,2% 2800 2800 3600 6600 2300 ±100
LP
(G31)
60000 1.06/5 5,2-14 inH
2
O
87000 1.10/8 5,2-14 inH
2
O
174000 1.20/15 5,2-14 inH
2
O 5,4% 10,2% 6300 87000 5,4% 10,2% 3900 3000 3900 6300 2300 ±100
81800 2.06 5,2-14 inH
2
O
95500 2.10 5,2-14 inH
2
O
190000 2.20 5,2-14 inH
2
O 5,1% 10,4% 6600 95500 5,8% 9,9% 2900 2900 3600 6600 2300 ±100