Loading...
Tools
Required
CAUTION
The
computer
and
bus
expander
use
metric
screws requiring
the
use
of
Pozidriv®
screwdrivers. Do
not
use
other
cross-tip screwdrivers,
such as Phillips
or
Reed-Prince, as
they
will eventually damage
the
Pozidriv®
heads.
The
following tools are required
to
access all field replaceable functional
and
mechanical assem-
blies:
Static-free Workstation,
HP
Part
Number
9300-0794
#1
Pozidriv®
screwdriver, 4-inch (100 mm) blade.
#2
Pozidriv®
screwdriver, 4-inch (100 mm) blade.
Flat-tip
screwdriver, 0.125-inch
(3
mm) wide tip, 4-inch (100 mm) blade.
Anti-Static Bags
Safety
Precautions
As
with
any electrical/electronic
product,
certain safety precautions
must
be
practiced.
These
safety precautions, when followed
protect
both
you
and
the
equipment from injury
and
danlage.
WARNING
Always
turn
off
the
equipment
and
remove ac power
cord
before open-
ing
the
computer/bus
expander
to
remove
or
replace
an
assembly.
If
maintenance
activity requires power
to
be
applied while
the
pro-
tective covers
are
removed, proceed only
with
extreme
caution
using
safe, live-unit
maintenance
procedures. Do
not
touch
energized com-
ponents
or
parts
with
your
fingers. Heed
and
follow all
"WARNING-
HAZARDOUS
VOLTAGE" labels. Failure
to
follow these safety pre-
cautions
may
result
in serious injury,
or
worse.
24
Assembly Replacement