11-36
Configuring Advanced Threat Protection
Using the Instrumentation Monitor
To enable instrumentation monitor using the default parameters and thresh-
olds, enter the general instrumentation monitor command. To adjust specific
settings, enter the name of the parameter that you wish to modify, and revise
the threshold limits as needed.
Examples
To turn on monitoring and event log messaging with the default medium
values:
HP Switch(config)# instrumentation monitor
To turn off monitoring of the system delay parameter:
HP Switch(config)# no instrumentation monitor system-
delay
To adjust the alert threshold for the MAC address count to the low value:
HP Switch(config)# instrumentation monitor mac-
address-count low
To adjust the alert threshold for the MAC address count to a specific value:
HP Switch(config)# instrumentation monitor mac-
address-count 767
To enable monitoring of learn discards with the default medium threshold
value:
HP Switch(config)# instrumentation monitor learn-
discards
To disable monitoring of learn discards:
HP Switch(config)# no instrumentation monitor learn-
discards
To enable or disable SNMP trap generation:
HP Switch(config)# [no] instrumentation monitor trap

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP E3800 Series and is the answer not in the manual?

HP E3800 Series Specifications

General IconGeneral
ModelHP E3800 Series
LayerLayer 3
Uplink Ports4 x SFP+ ports
StackingYes
Power over Ethernet (PoE)Available on some models
ManagementWeb, CLI, SNMP
Power SupplyRedundant (optional)
Operating Temperature0°C to 45°C
Dimensions (W x D x H)440 x 424 x 44 mm
Operating Humidity10% to 90% non-condensing

Related product manuals