14-38
Configuring and Monitoring Port Security
Reading Intrusion Alerts and Resetting Alert Flags
will see that the Intrusion Alert entry for port A1 has changed to “No”.
(Executing show port-security intrusion-log again will result in the same display
as above, and does not include the Intrusion Alert status.)
HP Switch(config)# port-security a1 clear-intrusion-flag
HP Switch(config)# show interfaces brief
Figure 14-17.Example of Port Status Screen After Alert Flags Reset
For more on clearing intrusions, see “Note on Send-Disable Operation” on
page 14-35.
Using the Event Log To Find Intrusion Alerts
The Event Log lists port security intrusions as:
W MM/DD/YY HH:MM:SS FFI: port 3 — Security Violation
where “
W” is the severity level of the log entry and FFI is the system module
that generated the entry. For further information, display the Intrusion Log,
as shown below.
From the CLI. Type the log command from the Manager or Configuration
level.
Syntax: log < search-text >
For < search-text >, you can use ffi, security, or violation. For example:
Intrusion Alert on port A1 is now
Status and Counters - Port Status
| Intrusion MDI Flow Bcast
Port Type | Alert Enabled Status Mode Mode Ctrl Limit
------------ --------- + --------- ------- ------ ---------- ---- ---- -----
1 100/1000T | No Yes UP 1000FDx Auto off 0
2 100/1000T | No Yes UP 1000FDx Auto off 0
3 100/1000T | No Yes Up 1000FDx Auto off 0

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP E3800 Series and is the answer not in the manual?

HP E3800 Series Specifications

General IconGeneral
ModelHP E3800 Series
LayerLayer 3
Uplink Ports4 x SFP+ ports
StackingYes
Power over Ethernet (PoE)Available on some models
ManagementWeb, CLI, SNMP
Power SupplyRedundant (optional)
Operating Temperature0°C to 45°C
Dimensions (W x D x H)440 x 424 x 44 mm
Operating Humidity10% to 90% non-condensing

Related product manuals