Item Description Status
4 Drive status LED O—The drive is not configured by a RAID controller
Solid green—The drive is a member of one or more logical
drives
Flashing green (4 Hz)—The drive is operating normally and
has activity
Flashing green (1 Hz)—The drive is rebuilding or
performing a RAID migration, stripe size migration, capacity
expansion, logical drive extension, or is erasing
Flashing amber/green (1 Hz)—The drive is a member of one
or more logical drives that predicts the drive will fail
Solid amber—The drive has failed
Flashing amber (1 Hz)—The drive is not configured and
predicts the drive will fail
5
Adapter ejection release latch and
handle
Removes the SFF flash adapter when released
Hot-plug fans
CAUTION: To avoid damage to server components, fan blanks must be installed in fan bays 1 and 2 in a single-
processor configuration.
CAUTION: To avoid damage to the equipment, do not operate the server for extended periods of time if the server
does not have the optimal number of fans installed. Although the server might boot, Hewlett Packard Enterprise
does not recommend operating the server without the required fans installed and operating.
The valid fan configurations are listed in the following tables.
One-processor configuration
Fan bay 1
Fan bay 2 Fan bay 3 Fan bay 4 Fan bay 5 Fan bay 6 Fan bay 7
Fan blank Fan blank Fan Fan Fan Fan Fan
Two-processor configuration
Fan bay 1
Fan bay 2 Fan bay 3 Fan bay 4 Fan bay 5 Fan bay 6 Fan bay 7
Fan Fan Fan Fan Fan Fan Fan