CAUTION: To prevent damage to electrical components, properly ground the server before beginning any
installation procedure. Improper grounding can cause electrostatic discharge.
2. Back up all server data.
3.
Power down the server.
4. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
5. Do one of the following:
a. Extend the server from the rack.
b.
Remove the server from the rack.
6. Remove the access panel.
7. Remove the primary PCI riser cage (
Remove the primary PCI riser cage).
8.
Install the card in the x16 slot in the primary PCI riser cage position.
9.
If installing a GPU requiring greater than 75 W, connect the power cable to the primary riser power connector.
10.
If the card requires rear support, install the GPU support bracket.
Hardware options installation
94