EN Horizontal Cursor Positioning (PCL Units) Command 6-7
Horizontal Cursor Positioning (PCL Units) 
Command 
This Horizontal Cursor Positioning command moves the cursor to a 
new position along the horizontal axis.
? * p # X
#  =   Number of PCL Units
Default = NA
Range = 0 - logical page right bound
A value field (#) with a plus sign (+) indicates the new position is to 
the right of and relative to the current cursor position; a minus sign (–) 
indicates the new position is to the left of and relative to the current 
cursor position. No sign indicates an absolute distance which is 
referenced from the left edge of the logical page. The left most 
position is 0 and the right most position is the right bound of the 
logical page.
If a request is made for a location outside the printer’s logical page, 
the current active position (CAP) is moved to the appropriate logical 
page limit.
Note The current unit size used in PCL Unit moves is determined by the 
value specified in the Unit of Measure command. If no other value is 
specified, the number of units-per-inch for PCL Unit moves is one unit 
equals 1/300 inch.