Error messages 138
1615-Power Supply Configuration Error
Audible Beeps: None
Possible Cause: The server configuration requires an additional power supply. A moving bar is displayed,
indicating that the system is waiting for another power supply to be installed.
Action: Install the additional power supply.
1615-Power Supply Configuration Error
- A working power supply must be installed in Bay 1 for proper cooling.
- System Halted!
Audible Beeps: None
Possible Cause: The server configuration requires an additional power supply. A moving bar is displayed,
indicating that the system is waiting for another power supply to be installed.
Action: Install the additional power supply.
1615-Power Supply Failure, Power Supply Unplugged, or Power Supply Fan
Failure in Bay X
Audible Beeps: None
Possible Cause: The power supply has failed, or it is installed but not connected to the system board or
AC power source.
Action: Reseat the power supply firmly and check the power cable or replace power supply.
1616-Power Supply Configuration Failure
-A working power supply must be installed in Bay 1 for proper cooling.
-System Halted!
Audible Beeps: None
Possible Cause: Power supply is improperly configured.
Action: Run the server setup utility and correct the configuration.
1700 Series
1704-Unsupported Virtual Mode Disk Operation DOS Driver Required
Audible Beeps: None
Possible Cause: The operating system currently running does not support virtual DMA service.
Action: Load or update the SCSI device driver appropriate for the operating system.
1706-Smart Array Controller Extended BIOS Data Area Memory Corrupted.
...Int 13h BIOS Cannot Continue - System Halted.