Error messages 95
Configuration Signature is Zero
Description: ADU ("Array diagnostic software" on page 76) detected that NVRAM contains a
configuration signature of zero. Old versions of the server setup utility could cause this.
Action: Run the latest version of server setup utility to configure the controller and NVRAM.
Configuration Signature Mismatch
Description: The array accelerator board is configured for a different array controller board. The
configuration signature on the array accelerator board does not match the one stored on the array
controller board.
Action: To recognize the array accelerator board, run ACU ("Array Configuration Utility" on page 70).
Controller Communication Failure Occurred
Description: Controller communication failure occurred. ADU was unable to successfully issue commands
to the controller in this slot.
Action:
1. Be sure all cables are properly connected and working.
2. Be sure the controller is working, and replace if needed.
Controller Detected. NVRAM Configuration not Present
Description: EISA NVRAM does not contain a configuration for this controller.
Action: Run the server setup utility to configure the NVRAM.
Controller Firmware Needs Upgrading
Description: Controller firmware is below the latest recommended version.
Action: Update the controller to the latest firmware version ("Firmware maintenance" on page 80).
Controller is Located in Special "Video" Slot
Description: Controller is installed in the slot for special video control signals. If the controller is used in
this slot, LED indicators on the front panel may not function properly.
Action: Install the controller into a different slot, and run the server setup utility to configure NVRAM. Then,
run ACU ("Array Configuration Utility" on page 70) to configure the controller.
Controller Is Not Configured
Description: Controller is not configured. If the controller was previously configured and you change drive
locations, a problem might exist with the placement of the drives. ADU ("Array diagnostic software" on
page 76) examines each physical drive and looks for drives that have been moved to a different drive
bay.
Action: Look for messages indicating which drives have been moved. If no messages are displayed and
drive swapping did not occur, run ACU ("Array Configuration Utility" on page 70) to configure the
controller and run the server setup utility to configure NVRAM. Do not run either utility if you believe drive
swapping has occurred.

Table of Contents

Other manuals for HP ProLiant BL620c - G7 Server

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant BL620c - G7 Server and is the answer not in the manual?

HP ProLiant BL620c - G7 Server Specifications

General IconGeneral
BrandHP
ModelProLiant BL620c - G7 Server
CategoryServer
LanguageEnglish

Related product manuals