Error messages 154
Audible Beeps: None
Possible Cause: A failed or replacement drive has not yet been rebuilt.
Action:
Perform one of the following actions:
o Press the F1 key to continue with recovery of data to the drive. Data will be automatically
restored to drive X when a failed drive has been replaced, or to the original drive if it is working
again without errors.
o Press the F2 key to continue without recovery of data to the drive. The failed drive will not be
rebuilt and the system will continue to operate in a failed state of Interim Data Recovery Mode.
Replace the failed drive and press the F1 key to rebuild the array. If the drive rebuild is not successful
or is aborted because the system rebooted before the rebuild of the drive completed, another version
of the 1786 POST error message will be displayed. Refer to the following message.
1786-Slot 1 Drive Array Recovery Needed. Automatic Data Recovery Previously
Aborted!...
...The following SCSI drive(s) need Automatic Data Recovery: SCSI Port Y: SCSI ID Z
Select F1 to retry Automatic Data Recovery to drive. Select F2 to continue without starting Automatic Data Recovery.
Audible Beeps: None
Possible Cause: System is in Interim Data Recovery Mode and a failed or replacement drive has not yet
been rebuilt. This message is displayed if the F2 key was pressed during a previous boot or if the F1 key
was pressed during a previous boot and the system rebooted before the rebuild of the drive completed.
Action:
Perform one of the suggested actions:
o Press the F1 key to retry Automatic Data Recovery to the drive. Data will be automatically
restored to drive X when a failed drive has been replaced, or to the original drive if it is working
again without errors.
o Press the F2 key to continue without recovery of data to the drive. The failed drive will not be
rebuilt and the system will continue to operate in a failed state of Interim Data Recovery Mode.
If drive recovery is not successful, run ADU ("Array diagnostic software" on page 76) for more
information.
o If the replacement drive failed, replace with another drive.
o If the rebuild was aborted due to a read error from another physical drive in the array, back up
all readable data on the array, run ADU, and then restore the data.
1787-Drive Array Operating in Interim Recovery Mode...
...Physical drive replacement needed: Drive X
Audible Beeps: None
Possible Cause: Hard drive X failed or cable is loose or defective. Following a system restart, this message
notes that drive X is defective and fault tolerance is being used.
Action:
1. Be sure all cables are connected properly and securely.
2. Test and replace defective cables.

Table of Contents

Other manuals for HP ProLiant BL620c - G7 Server

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant BL620c - G7 Server and is the answer not in the manual?

HP ProLiant BL620c - G7 Server Specifications

General IconGeneral
BrandHP
ModelProLiant BL620c - G7 Server
CategoryServer
LanguageEnglish

Related product manuals