Error messages 170
• Ensure proper ventilation and cooling for the server.
• Ensure the processor heatsinks are attached correctly (do not remove them).
• Check diagnostics and the Integrated Management Log for heat-related events.
• Upgrade to the latest versions of system BIOS and Insight Diagnostics.
• Replace the processor.
MSG_CPU_RR_2
Event type: A Pentium floating point bug exists.
Action: Replace the processor.
MSG_CPU_RR_3
Event type: Coprocessor geometric series is out of range.
Action:
• Ensure proper ventilation and cooling for the server.
• Ensure the processor heatsinks are attached correctly (do not remove them).
• Check diagnostics and the Integrated Management Log for heat-related events.
• Upgrade to the latest versions of system BIOS and Insight Diagnostics.
• Replace the processor.
MSG_CPU_RR_5
Event type: Refresh count is out of range.
Action: Replace the board that contains the memory controller.
MSG_CPU_RR_6
Event type: Unable to perform arithmetic operations on registers.
Action:
• Ensure proper ventilation and cooling for the server.
• Ensure the processor heatsinks are attached correctly (do not remove them).
• Check diagnostics and the Integrated Management Log for heat-related events.
• Upgrade to the latest versions of system BIOS and Insight Diagnostics.
• Replace the processor.
MSG_CPU_RR_7
Event type: CPU speed is out of range.
Action: Replace the processor.