Error messages 126
101-ROM Error
Audible Beeps: 1 long, 1 short
Possible Cause: System ROM checksum.
Action: Run Insight Diagnostics ("HP Insight Diagnostics" on page 75) and replace failed components as
indicated.
101-Option ROM Checksum Error...
...An add-in card in your system is not working correctly. If you have recently added new hardware, remove it and
see if the problem remains. If this message goes away after you remove your new hardware, there may be a
problem with the add-in card.
Audible Beeps: 1 long, 1 short
Possible Cause: An expansion board in the system is not working correctly.
Action: If you have recently added new hardware, remove it and see if the problem persists. If this
message goes away after you remove the new hardware, there may be a problem with the expansion
board. Review the expansion board documentation, and then try reinstalling the board.
102-System Board Failure
Audible Beeps: None
Possible Cause: 8237 DMA controllers, 8254 timers, and similar devices.
CAUTION: Only authorized technicians trained by HP should attempt to remove the system
board. If you believe the system board requires replacement, contact HP Technical Support
("Contacting HP" on page 173) before proceeding.
Action: Replace the system board. Run the server setup utility.
102-System Board Failure, CMOS Test Failed.
Audible Beeps: None
Possible Cause: 8237 DMA controllers, 8254 timers, and similar devices.
CAUTION: Only authorized technicians trained by HP should attempt to remove the system
board. If you believe the system board requires replacement, contact HP Technical Support
("Contacting HP" on page 173) before proceeding.
Action: Contact an authorized service provider for system board replacement.
102-System Board Failure, DMA Test Failed
Audible Beeps: None
Possible Cause: 8237 DMA controllers, 8254 timers, and similar devices.
CAUTION: Only authorized technicians trained by HP should attempt to remove the system
board. If you believe the system board requires replacement, contact HP Technical Support
("Contacting HP" on page 173) before proceeding.
Action: Contact an authorized service provider for system board replacement.

Table of Contents

Other manuals for HP ProLiant BL620c - G7 Server

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP ProLiant BL620c - G7 Server and is the answer not in the manual?

HP ProLiant BL620c - G7 Server Specifications

General IconGeneral
BrandHP
ModelProLiant BL620c - G7 Server
CategoryServer
LanguageEnglish

Related product manuals