EasyManua.ls Logo

HP ProLiant BL620c - G7 Server

HP ProLiant BL620c - G7 Server
190 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Error messages 149
Expansion will resume when Array Accelerator battery reaches full charge.
Expansion will resume when automatic data recovery has been completed.
Audible Beeps: None
Possible Cause: The capacity expansion process has been temporarily disabled.
Action: Follow the action that is displayed onscreen to resume the capacity expansion process.
1768-Slot X Drive Array - Resuming Logical Drive Expansion Process
Audible Beeps: None
Possible Cause: Power was lost while a logical expansion operation was performed. A controller reset or
power cycle occurs while array expansion is in progress.
Action: No action is required.
1769-Slot X Drive Array - Drive(s) Disabled Due to Failure During Capacity
Expansion
...Select F1 to continue with logical drives disabled. Select F2 to accept data loss and to re-enable logical drives.
Audible Beeps: None
Possible Cause: Data was lost while the array was expanded; therefore, the drives have been temporarily
disabled. Capacity expansion failed due to:
Array accelerator or hard drive failed or was removed; expansion progress data lost
Expansion progress data could not be read from array accelerator
Expansion aborted due to unrecoverable drive errors
Expansion aborted due to array accelerator errors
Action:
Press the F2 key to accept the data loss and re-enable the logical drives.
Restore data from backup.
Replace drive or array accelerator, as appropriate.
1770-Slot X Drive Array - SCSI Drive Firmware Update Recommended - ...
...Please upgrade firmware on the following drive(s) using ROM Flash Components (download from
www.hp.com/support/proliantstorage): Model XYZ (minimum version = ####)
Audible Beeps: None
Possible Cause: Drive firmware update needed.
Action: The indicated drives are running firmware that is known to cause intermittent problems. Update all
drives to the latest firmware version ("Firmware maintenance" on page 80).

Table of Contents

Other manuals for HP ProLiant BL620c - G7 Server

Related product manuals