Installing an energy packInstalling an energy pack
PrerequisitesPrerequisites
Before you perform this procedure:
Make sure that a Smart Array P-class type-p Gen10 controller is installed .
Make sure that you have the following items available:
Storage controller backup power cable (ships with the storage controller)
Energy pack option
If you are installing the HPE Smart Storage Hybrid Capacitor, verify that the system BIOS meets the minimum firmware
requirements.
ProcedureProcedure
1. Power down the server
.
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect all peripheral cables from the server.
4. Do one of the following:
If the server is in tower mode: Position the tower server for hardware configuration.
If the server is in rack mode: Remove the server from the rack .
5. Remove the front bezel
.
6. Remove the access panel
.
7. If installed, remove the air baffle
.
8. Remove the black tapes from the chassis.
9. Install the energy pack holders.
Installing an energy pack 131