Factory port threshold alarm configuration
Enter show config threshold CLI command to display threshold alarm configuration values. If the
ThresholdMonitoringEnabled parameter is disabled (False), none of the individual threshold monitoring
parameter settings can be applied.
Factory zoning configuration
Enter the show config zoning CLI command to display zoning configuration values.
Table 19 Port threshold alarm configuration defaults
Parameter Default
ThresholdMonitoringEnabled False
CRCErrorsMonitoringEnabled
RisingTrigger
FallingTrigger
SampleWindow
True
25
1
10
DecodeErrorsMonitoringEnabled
RisingTrigger
FallingTrigger
SampleWindow
True
25
0
10
ISLMonitoringEnabled
RisingTrigger
FallingTrigger
SampleWindow
True
2
0
10
LoginMonitoringEnabled
RisingTrigger
FallingTrigger
SampleWindow
True
5
1
10
LogoutMonitoringEnabled
RisingTrigger
FallingTrigger
SampleWindow
True
5
1
10
LOSMonitoringEnabled
RisingTrigger
FallingTrigger
SampleWindow
True
100
5
10
Table 20 Zoning configuration defaults
Parameter Default
MergeAutoSave True
DefaultZone Allow
DiscardInactive False

Table of Contents

Other manuals for HP StorageWorks SN6000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP StorageWorks SN6000 and is the answer not in the manual?

HP StorageWorks SN6000 Specifications

General IconGeneral
BrandHP
ModelStorageWorks SN6000
CategorySwitch
LanguageEnglish

Related product manuals