Factory SNMP configuration
Enter the show setup snmp CLI command to display SNMP configuration values.
Table 21 SNMP configuration defaults
Parameter Default
SNMPEnabled True
Contact <syscontact undefined>
Location <sysLocation undefined>
Description For AW575A and BK780A:
HP StorageWorks SN6000
Stackable Single Power Supply
Fibre Channel Switch
For AW576A:
HP StorageWorks SN6000
Stackable Dual Power Supply
Fibre Channel Switch
ObjectID HP StorageWorks SN6000
Stackable Single Power Supply
Fibre Channel Switch:
1.3.6.1.4.1.3873.1.24
HP StorageWorks SN6000
Stackable Dual Power Supply
Fibre Channel Switch:
1.3.6.1.4.1.3873.1.25
AuthFailureTrap False
ProxyEnabled True
SNMPv3Enabled False
Trap [1-5] Address Trap 1: 10.0.0.254
Traps 2–5: 0.0.0.0
Trap [1-5] Port 162
Trap [1-5] Severity Warning
Trap [1-5] Version 2
Trap [1-5] Enabled False