Operating power supply failure on the HPE
FlexNetwork 5130 24G SFP 4SFP+ EI Switch
(JG933A)
Symptom
A trap or log is generated indicating that an operating power supply is faulty.
Solution
To resolve the problem:
1. Execute the display power command to display power supply information.
<Sysname> display power
Slot 1:
PowerID State Mode Current(A) Voltage(V) Power(W)
1 Normal DC -- -- 0
2 Fault AC -- -- 0
If the power supply is in Absent state, go to step 2. If the power supply is in Fault state, go to
step 3.
2. Remove a
nd reinstall the power supply to make sure the power supply is installed correctly.
Then, execute the display power command to verify that the power supply has changed to
Normal state. If the power supply remains in Absent state, replace the power supply.
3. When the power supply is in Fault state, perform the following steps:
a. Verify that the power supply has not been disconnected from the power source. If it has
been disconnected from the power source, connect the power source to it.
b. Verify that the power supply surface is clean. If there is dust accumulated on the power
supply, remove the dust. Then remove and reinstall the power supply. Execute the display
power command to verify that the power supply has changed to Normal state. If the power
supply remains in Fault state, go to step c.
c. Install the po
wer supply into an empty power supply slot. Then execute the display power
command to verify that the power supply has changed to Normal state in the new slot. If the
power supply remains in Fault state, replace the power supply.
4. If the problem persists, contact Hewlett Packard Enterprise Support.
Newly-installed power supply failure on the HPE
FlexNetwork 5130 24G SFP 4SFP+ EI Switch
(JG933A)
Symptom
A trap or log is generated indicating that a newly-installed power supply is faulty.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HPE FlexNetwork 5130 Series and is the answer not in the manual?

HPE FlexNetwork 5130 Series Specifications

General IconGeneral
CategoryNetwork Switch
Ports24 or 48 10/100/1000 ports
Uplink Ports4 x SFP+ ports
Routing ProtocolStatic routing, RIP, OSPF, BGP
PoEAvailable on some models (PoE+)
Input Voltage100-240 VAC
Operating Temperature0°C to 45°C
ManagementWeb, CLI, SNMP
Jumbo Frame SupportYes
VLANs4094
Operating Humidity5% to 95% (noncondensing)

Related product manuals