2. Insert the SSD into the M.2 slot at a 45° angle (callout 1).
3. Carefully press the SSD down to the horizontal position (callout 2).
4. Install the SSD mounting screw (callout 3).
5. If you are installing a second SSD, repeat steps 2–4 on the slot 2.
Installing the M.2 pass-through cardInstalling the M.2 pass-through card
6. If physically powering down a server with the front bezel installed, remove the front bezel .
7. Power down the server.
8. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
9. Disconnect all peripheral cables from the server.
10. Remove the server from the rack .
11. Place the server on a flat, level work surface.
12. Remove the access panel .