IMPORTANT:IMPORTANT: The fan setup can either be all 7 of standard or high performance fans. Do not mix fan types in the same
server.
ProcedureProcedure
1. Power down the server.
2. If installed, open the cable management arm .
3. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4. Disconnect all peripheral cables from the server.
5. Remove the server from the rack .
6. Place the server on a flat, level work surface.
7. Remove the access panel .
8. Remove the M.2 air baffle .
9. Remove the fan.
ResultsResults
To replace the component, reverse the removal procedure.
Removing and replacing the fan boardRemoving and replacing the fan board
PrerequisitesPrerequisites
Before you perform this procedure, make sure that you have a T-15 Torx screwdriver available.
About this taskAbout this task
ProcedureProcedure
1. Power down the server.
2. If installed, open the cable management arm .