HPE ProLiant DL388 Gen10 - Removing and Replacing the Flexiblelom

HPE ProLiant DL388 Gen10
169 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CAUTION: Do not operate the server for long periods with the access panel open or removed.
Operating the server in this manner results in improper airflow and improper cooling that can lead to
thermal damage.
IMPORTANT: For optimum cooling, install fans in all primary fan locations.
For more information, refer to the fan locations table in the server user guide.
To replace the component, reverse the removal procedure.
Removing and replacing the FlexibleLOM
Procedure
1. Power down the server (Powering down the server on page 41).
2. Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
3. Disconnect the LAN segment cables.
4. Do one of the following:
• Extend the server from the rack (Extend the server from the rack on page 42).
• Remove the server from the rack (Remove the server from the rack on page 42).
5. Remove the FlexibleLOM.
62 Removal and replacement procedures