20.
IMPORTANT: Install all components with the same configuration that was used on the failed
system board.
Install all components removed from the failed system board.
21. Install the access panel.
22. Install the power supplies.
23. Power up the server.
24. Ensure all firmware, including option cards and embedded devices, is updated to the same versions to
ensure that the latest drivers are being used.
25. Re-enter any Secure Boot Keys that were previously added in the Secure Boot configuration.
26. Re-enter the server serial number and the product ID (Re-entering the server serial number and
product ID on page 98).
27. For servers that support Scalable Persistent Memory, restore the logical NVDIMMs from the last Scalable
Persistent Memory backup operation (Restoring logical NVDIMMs after system board replacement
on page 99).
Re-entering the server serial number and product ID
After you replace the system board, the server serial number and the product ID must be configured:
Procedure
1. Access System Utilities. During POST, press F9.
2. On the System Utilities home screen, select System Configuration > BIOS/Platform Configuration
(RBSU) > Advanced Options > Advanced Service Options.
3. Select the Serial Number field and press Enter.
The following alert appears:
The serial number is modified by qualified service personnel and must match
the serial number located on the chassis.
98 Removal and replacement procedures