Appendix A Parameters Shenzhen Hpmont Technology Co., Ltd
―130― HD20 Series Inverters User Manual
No. Name Range
Factory
Default
Unit
Modified
attributes
Setting
F07.01 Wobble operation mode
1: The inverter restarts the
wobble operation from 0 Hz
Thousands: Save the wobble
operation parameters at power
outage
0: Saved
1: Not be saved
0000 1 ×
F07.02 Preset wobble frequency 0.00-upper limit 0.00Hz 0.01Hz ×
F07.03
Holding time of preset
wobble frequency
0.0-999.9s 0.0s 0.1s ×
F07.04 Wobble amplitude 0.0-50.0% 0.0% 0.1% ×
F07.05 Jump frequency 0.0-F07.04 0.0% 0.1% ×
F07.06 Wobble operation cycle 0.01-600.00s 10.00s 0.01s ×
F07.07
Rising time of triangle
wave
0.0-100.0%(F07.06) 50.0% 0.1% ×
Group F08 Asynchronous Motor 1 Parameters (refer to pages 70
72)
F08.00 Rated power of motor 1 0.2-11.0kW
Dependent
on inverter
model
0.1kW ×
F08.01 Rated voltage of motor 1 0-999V 1V ×
F08.02 Rated current of motor 1 0.01-99.99A 0.01A ×
F08.03
Rated frequency of motor
1
1.0-400.0Hz 50.0Hz 0.1Hz ×
F08.04 Rated speed of motor 1 1-24000rpm 1500rpm 1rpm ×
F08.05 Power factor of motor 1 0.001-1.000
Dependent
on inverter
model
0.001 ×
F08.06
Parameter auto-tuning of
motor 1
0: Auto-tuning is disabled
1: Stationary auto-tuning
2: Rotary auto-tuning
0 1 ×
F08.07
Stator resistance of motor
1
0.00-99.99Ω
Dependent
on inverter
model
0.01Ω ×
F08.08
Rotor resistance of motor
1
0.00-99.99Ω 0.01Ω ×
F08.09
Leakage inductance of
motor 1
0-9999mH 1mH ×
F08.10
Mutual inductance of
motor 1
0-5000mH 1mH ×
F08.11
Idling exciting current of
motor 1
0.00-99.99A 0.01A ×
F08.12 Reserved
F08.13 Reserved
F08.14 Reserved
Group F09 V/f Control Parameters (refer to pages 72
74)
F09.00
V/f curve selection of
0: Line 0 1 ×