Procedure
Step 1 Install an optical module, as shown in Figure 4-33 and Figure 4-34.
1. Remove the dust-proof cap from the CPRI port on the RHUB panel.
2. Remove the dust-proof cap on the optical module.
3. Lower the puller of the optical module.
4. Insert the optical module into the CPRI port on the RHUB, BBU or ODF.
5. Raise the puller of the optical module.
Figure 4-33 Removing the dust-proof cap from a port
Figure 4-34 Installing an optical module
Step 2 Install a CPRI optical cable, as shown in Figure 4-35.
1. Remove the dust-proof cap from the optical cable connector.
2. Install the optical cables by referring to Table 4-3.
Table 4-3 CPRI optical cable connections
One End The Other End
Connect
or
Connected to Connector Connected to
DLC
connecto
r
BBU/
LBBP&WBBP&UBBP/
CPRI port
DLC connector CPRI0 or CPRI1 port on
the RHUB
CPRI0 or CPRI1 port on the
RHUB
CPRI0 or CPRI1 port on
the RHUB