● A meter must be congured for the dynamic charging power function. When
the char
ger detects that the meter is disconnected, it switches to the
minimum current charging mode. You can also set Charging current if
charger is disconnected from meter as needed.
Parameter Settings (Installer)
When creating a PV plant, log in to the FusionSolar app as an installer, connect to
the charger, tap Setup Wizard on the home screen, and set Main Circuit
Breaker Capacity on the quick settings screen.
Figure 2-7 Quick settings
Alternatively, c
onnect to the charger as an installer, set Main Circuit Breaker
Capacity and Charging current if charger is disconnected from meter on the
maintenance screen.
PV+ESS+Charger Solution
User Manual 2 Solution Overview
Issue 02 (2023-01-13) Copyright © Huawei Technologies Co., Ltd. 23