Parameter Description
Q-U characteristic curve The inverter adjusts Q/S (the ratio of the output reactive
power to apparent power) in real time based on U/Un(%)
(the ratio of the actual power grid voltage to the rated
power grid voltage).
Q-P characteristic curve The inverter adjusts Q/Pn (the ratio of the output reactive
power to the rated active power) in real time based on P/
Pn(%) (the ratio of the actual active power to the rated
active power).
Cosφ-P/Pn characteristic curve The inverter adjusts the output power factor cosφ in real
time based on P/Pn(%).
----End
7.2 Operations with a USB Flash Drive
USB ash drives of SanDisk, Netac, or Kingston are supported. Other USB ash
drives may not be identied because they are not tested for compatibility.
Delete the script le immediately after use to reduce information disclosure risks.
7.2.1 Exporting Congurations
Procedure
1. Click Local maintenance script on the app to generate a boot script
le, see
the
FusionSolar APP and SUN2000 APP User Manual
.
2. Import the boot script le to a PC.
(Optional) The boot script le can be opened as a .txt le.
Figure 7-14 Boot script le
SUN2000-(90KTL, 95KTL, 100KTL, 105KTL) Series
User Manual
7 Man-Machine Interactions
Issue 11 (2020-08-30) Copyright © Huawei Technologies Co., Ltd. 90