SUN2000L-(4.125KTL, 4.95KTL)-JP
User Manual
7 Operations on the Local FusionHome App
Huawei Proprietary and Confidential
Copyright © Huawei Technologies Co., Ltd.
86
Method 2: use the saved file
Before choosing Use saved file for quick setting, ensure that the corresponding configuration
file is saved in your mobile phone. To generate a configuration file, tap Save settings on the
Quick setting screen.
Step 1 Choose Quick setting > Use saved file from the Operation console screen and perform
deployment by following the instructions.
Figure 7-27 Performing quick setting using a saved file
To change the configuration file to be imported, tap Change.
In the dialog box with Are you sure you want to configure the inverter connected router settings
again, if you tap Confirm, the router configurations saved before will be cleared. If you tap Cancel,
you only have to enter the saved router password.
After the connected router is configured, the configuration takes effect after you log out of the app
and then log in again.
After the management system is successfully connected, the SUN2000L will report the SN and
installer registration code number. If the connection fails, another connection attempt will start after
10 seconds. The installer registration code number is generated by the SUN2000L automatically and
is used for the installer to register with the management system and manage the inverter.
----End

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Huawei SUN2000L Series and is the answer not in the manual?

Huawei SUN2000L Series Specifications

General IconGeneral
Max. DC Voltage600 V
Max. Efficiency98.6%
CoolingNatural Convection
Protection DegreeIP65
Power Output Range2kW - 5kW
Max. AC Power5, 500 VA
Rated AC Voltage220 V / 230 V
European Efficiency98.2%
Operating Temperature Range-25°C to +60°C
Weight10.6 kg